5000 Series Digital IO
 

Product HAZLOC Certifications General Area Safety Certifications
5401 

Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.
 

cULus Listed to the following standards:
- CSA Std. C22.2 No. 213-M1987 - Hazardous Locations.
- CSA Std. C22.2 No. 142-M1987 - Process Control Equipment.
- UL Std. No. 1604 - Hazardous (Classified) Locations.
- UL Std. No. 508 - Industrial Control Equipment.

 
5402 

Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.
 

cCSAus certified to the requirements of:
- CSA Std. C22.2 No. 213-M1987 - Hazardous Locations.
- CSA Std. C22.2 No. 142-M1987 - Process Control Equipment.
- UL Std. No. 1604 - Hazardous (Classified) Locations.
- UL Std. No. 916 – Energy Management Equipment.
 

 
5403 

Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.


cULus Listed to the following standards:
- CSA Std. C22.2 No. 213-M1987 - Hazardous Locations.
- CSA Std. C22.2 No. 142-M1987 - Process Control Equipment.
- UL Std. No. 1604 - Hazardous (Classified) Locations.
- UL Std. No. 508 - Industrial Control Equipment

 
5404 

Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.

cCSAus certified to the requirements of:
- CSA Std. C22.2 No. 213-M1987 - Hazardous Locations.
- CSA Std. C22.2 No. 142-M1987 - Process Control Equipment.
- UL Std. No. 1604 - Hazardous (Classified) Locations.
- UL Std. No. 916 – Energy Management Equipment

 
5405 

North America: Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations. Temperature Code T4.
UL Listed and CSA certified to the following standards:
- CSA Std. C22.2 No. 213-M1987 - Hazardous Locations.
- CSA Std. C22.2 No. 142-M1987 - Process Control Equipment.
- UL Std. No. 1604 - Hazardous (Classified) Locations.
- UL Std. No. 508 - Industrial Control Equipment.
 

Europe: 5405-24 (24V DI version) only: ATEX II 3G, Ex nA IIC T4 per EN 60079-15, protection type n (Zone 2).
 

International: IECEx, Ex nA IIC T4 per IEC 60079-15, protection type n (Zone 2)

Canada and US: CSA C22.2 No. 142-M1987 and UL916. UL508

5410 

Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.


cCSAus certified to the requirements of:
- CSA Std. C22.2 No. 213-M1987 - Hazardous Locations.
- CSA Std. C22.2 No. 142-M1987 - Process Control Equipment.
- UL Std. No. 1604 - Hazardous (Classified) Locations.
- UL Std. No. 916 – Energy Management Equipment

 
5414 

North America: cCSAus suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations. Temperature Code T4 per CSA Std C22.2 No. 213-M1987 / UL1604.

Europe: 5414-24 (24V DI version) only: ATEX II 3G: Ex nA IIC T4 per EN 60079-15, protection type n (Zone 2).

International: IECEx, Ex nA IIC T4 per IEC 60079-15, protection type n (Zone 2)

CSA C22.2 No. 142-M197 and UL916 in Canada and USA.
Maximum permitted voltage outside of Canada or USA is 30 V ac/42.4 V pk/60 V dc.


UL508.

 

5421 

Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.


cULus Listed to the following standards:
- CSA Std. C22.2 No. 213-M1987 - Hazardous Locations.
- CSA Std. C22.2 No. 142-M1987 - Process Control Equipment.
- UL Std. No. 1604 - Hazardous (Classified) Locations.
- UL Std. No. 508 - Industrial Control Equipment.

 
5406  Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.   
5406A  Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.
Temperature Code T5 at 70oC ambient. 
 
5407  Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.   
5408  Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.   
5409  Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations.   
5411 

North America: cCSAus Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations. Temperature Code T4 per CSA Std C22.2 No. 213-M1987 / UL1604.

Europe: 5414-24 (24V DI version) only: ATEX II 3G, Ex nA IIC T4 per EN 60079-15, protection type n (Zone 2).

International: IECEx, Ex nA IIC T4 per IEC 60079-15, protection type n (Zone 2)

Canada and US: CSA C22.2 No. 142-M197 and UL916. UL508.

5415 

North America: cCSAus Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations. Temperature Code T4 per CSA Std C22.2 No. 213-M1987 / UL1604.

Europe: 5415 SSR version only:
ATEX II 3G, Ex nA IIC T4 per EN 60079-15, protection type n (Zone 2).

International: 5415 SSR version only:
IECEx, Ex nA IIC T4 per IEC 60079-15, protection type n (Zone 2)

CSA C22.2 No. 142-M197 and UL916 in Canada and USA.
Maximum permitted voltage outside of Canada or USA is 30 V ac/42.4 V pk/60 V dc.
 

UL508.