SCADAPack 4203 and Transmitters


 

 

Product HAZLOC Certifications General Area Safety Certifications
4203 DR & DS 

North America: cCSAus Explosion proof. Class I, Div. 1 Groups B, C and D Hazardous Locations.
cCSAusClass I, Div. 2 Groups A, B, C and D Hazardous Locations.
Temperature code T5 at maximum ambient, 70°C.
Provides non-incendive field circuits for RTD.

Europe: ATEX Ex d IIC T6; -50°C ≤ Ta ≤ 70°C per EN 60079-1, protection type d (Flameproof).

International: IECEx Ex d IIC T6; -50°C ≤ Ta ≤ 70°C per IEC 60079-1, protection type d (Flameproof)

CSA certified to the following standards:
- CSA Std. C22.2 No. 213-M1987 - Class I, Division 2 Hazardous Locations
- CSA Std. C22.2 - No. 142-M1987 - Process Control Equipment
- UL Std. No. 1604 - Class I and II, Division 2; Class III Hazardous (Classified) Locations
- UL Std No. 916 - Energy Management Equipment.

4012 

 

North America: cCSAus Explosion proof. Class I, Div. 1 Groups B, C and D Hazardous Locations.
cCSAusClass I, Div. 2 Groups A, B, C and D Hazardous Locations.
Temperature code T5 at maximum ambient, 70°C.
Provides non-incendive field circuits for RTD.

 

Europe: ATEX: Ex d IIC T6; -20°C ≤ Ta ≤ 70°C per EN 60079-1, protection type d (Flameproof).

CSA certified to the following standards:
- CSA Std. C22.2 No. 213-M1987 - Class I, Division 2 Hazardous Locations
- CSA Std. C22.2 - No. 142-M1987 - Process Control Equipment
- UL Std. No. 1604 - Class I and II, Division 2; Class III Hazardous (Classified) Locations
- UL Std No. 916 - Energy Management Equipment. 

4032 

 

cCSAus Explosion proof. Class I, Div. 1 Groups B, C and D Hazardous Locations.
cCSAusClass I, Div. 2 Groups A, B, C and D Hazardous Locations.
Temperature code T5 at maximum ambient, 70°C.
Provides non-incendive field circuits for RTD.

 

Europe: ATEX Ex d IIC T6; -50°C ≤ Ta ≤ 70°C per EN 60079-1, protection type d (Flameproof).

International: IECEx Ex d IIC T6; -50°C ≤ Ta ≤ 70°C per IEC 60079-1, protection type d (Flameproof)

CSA certified to the following standards:
- CSA Std. C22.2 No. 213-M1987 - Class I, Division 2 Hazardous Locations
- CSA Std. C22.2 - No. 142-M1987 - Process Control Equipment
- UL Std. No. 1604 - Class I and II, Division 2; Class III Hazardous (Classified) Locations
- UL Std No. 916 - Energy Management Equipment. 

4102 

 

 

North America: cCSAus Explosion proof. Class I, Div. 1 Groups B, C and D Hazardous Locations.
cCSAusClass I, Div. 2 Groups A, B, C and D Hazardous Locations.
Temperature code T5 at maximum ambient, 70°C.
Provides non-incendive field circuits for RTD.

 

Europe: ATEX Ex d IIC T6; -50°C ≤ Ta ≤ 70°C per EN 60079-1, protection type d (Flameproof). International: IECEx Ex d IIC T6; -50°C ≤ Ta ≤ 70°C per IEC 60079-1, protection type d (Flameproof).

CSA certified to the following standards:
- CSA Std. C22.2 No. 213-M1987 - Class I, Division 2 Hazardous Locations
- CSA Std. C22.2 - No. 142-M1987 - Process Control Equipment
- UL Std. No. 1604 - Class I and II, Division 2; Class III Hazardous (Classified) Locations
- UL Std No. 916 - Energy Management Equipment.