Downloads

Series 5000 Product Selection Guide

SCADAPack - 5000 Series Module Compatibility Chart

FreeWave Tool Suite

Application Notes

Product Feedback

General Inquiries

Write a Testimonial !

The following are expansion modules available for use with Control Microsystems SCADAPack Controllers:

Analog Input Modules

 

Analog Output Modules

 

Digital Input Modules

 

 

Digital I/O Modules

Digital Output Modules

 

Combination I/O Modules

 

I/O Simulator Modules

 

UPS Power Supply

 

Non-Programmable Controller Modules

 

Analog Input Modules

Module 5502

Differential Analog Input Module
Features:

  • Differential Isolated Inputs for high versatility
  • Integrated transient protection with fusing
  • Bipolar 13 bit resolution
  • High common mode voltage rejection and tolerance
  • 3 year warranty on parts and labor

Module 5502 PDF Datasheet

 



Module 5504
Thermocouple Input Module
Features:
  • Eight type J, K, T, E or ±80 mV inputs
  • Optical isolation for high reliability
  • Integrated transient protection
  • Linearized and cold junction compensated
  • 3 year warranty on parts and labor
     

Module 5504 PDF Datasheet



Module 5505
RTD Input Module
Features:

  • Input values scaled and linearized
  • Data returned as 32-bit floating-point number
  • Lower power consumption
  • Automatic 3-wire RTD compensation
  • 5503 emulation mode for legacy systems
  • ATEX ll 3G and IECEx: Ex nA llC T4 per EN 60079-15, protection type n (Zone 2)
  • UL508 listed
  • 3 year warranty on parts and labor
     

Module 5505 PDF Datasheet

 


Module 5506
Analog Input Module
Features:
  • 0 to 20mA / 4 to 20mA inputs
  • 0 to 5V / 1 to 5V inputs
  • Individual input configuration
  • 5501 emulation mode for legacy systems
  • ATEX ll 3G and IECEx: Ex nA llC T4 per EN 60079-15, protection type n (Zone 2)
  • UL Listed
  • 3 year warranty on parts and labor

 

 

Module 5506 PDF Datasheet

Analog Output Modules


Module 5302
Analog Output Module
Features:
  • 20mA current
  • Low power
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor

Module 5302 PDF Datasheet

 


Module 5304
Analog Output Module
Features:
  • Selectable voltage and current modes
  • 5V and 10V selectable voltage modes
  • Low power
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • ATEX ll 3G and IECEx: Ex nA llC T4 per EN 60079-15, protection type n (Zone 2)
  • 3 year warranty on parts and labor

 

 

Module 5304 PDF Datasheet

Digital Input Modules


Module 5403
High Level Digital Input Module
Features:
  • Reliable optical isolation
  • Isolated in groups of 4 for ease of wiring
  • Very low power requirements
  • Universal AC or DC
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor

Module 5403 PDF Datasheet

 


Module 5404
High Level Digital Input Module
Features:
  • 16 optically isolated digital inputs
  • Isolated in groups of 4 for ease of wiring
  • Very low power requirements
  • 12 to 240 volts
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor

Module 5404 PDF Datasheet

 


Module 5405
Digital Input Module
Features:
  • High density, 32 digital inputs
  • Sinking input design
  • Low power
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • ATEX ll 3G and IECEx: Ex nA llC T4 per EN 60079-15, protection type n (Zone 2)
  • 3 year warranty on parts and labor
     

Module 5405 PDF Datasheet

 


Module 5410
High Speed Counter/Accumulator
Features:
  • Optically isolated
  • 32 bit count range
  • Wide input range 3 VDC - 28 VDC
  • Guaranteed no missed counts to 10KHz
  • Count retained during power outage
  • Self clearing or accumulating
  • Accepts quadrature phase inputs
  • 3 year warranty on parts and labor

 

Module 5410 PDF Manual

 


Module 5414
Compact Digital Input Module
Features:
  • 16 optically-isolated digital inputs
  • 12 to 240 volts
  • Universal AC or DC
  • Very low power requirements
  • Compact module
  • Class I, Division 2 Groups A, B, C and D Hazardous Locations
  • CSA certified to UL508 standards
  • UL508 listed
  • ATEX ll 3G and IECEx: Ex nA llC T4 per EN 60079-15, protection type n (Zone 2) (5414-24 only)
  • 3 year warranty on parts and labor

 

Note: Not supported by 16-bit SCADAPack controllers

Module 5414 PDF Datasheet

 

Digital I/O Modules


Module 5401
Configurable Digital I/O Module
Features:
  • Most cost-effective for low point counts
  • Each point can be input or output
  • Plug-in relays simplify maintenance
  • High current outputs to 3A
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor

Module 5401 PDF Datasheet

 


Module 5402
Configurable Digital Input
or Output Module
Features:
  • 16 configurable digital inputs or outputs
  • Each point can be AC or DC
  • Plug-in relays simplify maintenance
  • High current outputs to 3A
  • 3 year warranty on parts and labor

 

 

Module 5402 PDF Datasheet

Digital Output Modules


Module 5406
Dry Contact Relay Out Module
Features:
  • 16 mechanical relays
  • Highest output load current
  • Zero leakage current
  • Individually isolated
  • Modifiable for Form B (NC) operation
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor
     

Module 5406 PDF Datasheet



Module 5407
Dry Contact Relay Out Module
Features:
  • Highest output load current
  • Zero leakage current
  • Individually isolated
  • Modifiable for Form B (NC) operation
  • Relays sealed against corrosion
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor

Module 5407 PDF Datasheet

 


Module 5408
Triac Digital Output Module
Features:
  • Optical isolation
  • Snubbers for inductive loads
  • MOV transient suppression
  • Zero-crossing turn on/off for low EMF
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor
     

Module 5408 PDF Datasheet

 


Module 5409
FET Digital Output Module
Features:
  • 8 isolated DC outputs
  • Optical isolation
  • Diode protected for inductive loads
  • Power source LED
  • 3 year warranty on parts and labor
     

Module 5409 PDF Datasheet



Module 5411
Digital Output Module
Features:
  • High density, 32 digital outputs
  • Sinking output design
  • Low power
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • ATEX ll 3G and IECEx: Ex nA llC T4 per EN 60079-15, protection type n (Zone 2)
  • 3 year warranty on parts and labor

 

 

Module 5411 PDF Datasheet


Module 5415
Compact Relay Digital Output Module
Features:
  • 12 relay digital outputs
  • Dry Contact or Solid State Relay versions
  • Isolated in 3 groups of 4
  • Very low power requirements
  • Compact module
  • Class I, Division 2 Groups A, B, C and D Hazardous Locations
  • CSA certified to UL508 standards
  • UL508 listed
  • ATEX ll 3G and IECEx: Ex nA llC per EN 60079-15, protection type n (Zone 2) , (5415-A only)
  • 3 year warranty on parts and labor

 

Note: Not supported by 16-bit SCADAPack controllers

Module 5415 PDF Datasheet

 

Combination I/O Modules


Module 5606
Analog/Digital I/O Module
Features:

  • High density IO combination board
  • 32 DIs
  • 16 Relay DOs
  • 8 Configurable AIs
  • 2 Optional AOs
  • Up to 8 modules supported
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • ATEX ll 3G and IECEx: Ex nA llC T4 per EN 60079-15, protection type n (Zone 2),
    (24VDI/Solid State Relay type only)
  • 3 year warranty on parts and labor

 

Module 5606 PDF Datasheet


Module 5607
Analog/Digital I/O Module
Features:

  • High density IO combination board
  • 16 DIs
  • 10 Relay DOs (Dry Contact or Solid State versions)
  • 8 Configurable AIs
  • 2 Optional AOs
  • Up to 8 modules supported
  • Class I, Division 2 Groups A, B, C and D Hazardous Locations
  • CSA certified to UL508 standards
  • ATEX ll 3G and IECEx: Ex nA llC T4 per EN 60079-15, protection type n (Zone 2),
    (24VDI/Solid State Relay type only)
  • 3 year warranty on parts and labor

5607

Module 5607 PDF Datasheet

 

I/O Simulator Modules

Module 5421
Toggle Switch Digital Input Module
Features:

  • Reliable, sealed toggle switches
  • Ideal for simulation, testing
  • Status LEDs show switch position
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor

Module 5421 PDF Datasheet



Module 5521
Potentiometer Input Module
Features:

  • Multi-turn pots aid adjustment
  • 12 bit resolution
  • Does not require 24V power
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor

 

 

Module 5521 PDF Datasheet

UPS Power Supply


Module 5103
Uninterruptible Power Supply
Features:

  • Transformer isolated
  • Built-in battery charger for UPS
  • Isolated 24 volt analog loop output
  • Dual, wide range AC/DC inputs
  • Cool running switch-mode design
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor

Module 5103 PDF Datasheet

 

Non-Programmable Controller Modules


Module 5201
RS-485 Communication Controller
Features:

  • Simple configuration - no programming required
  • Powerful industry-standard protocol
  • Supports 64 AI, 64 DI, 64 DO, 32 AO
  • Watchdog timer
  • Power saving LED control
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor
     

Module 5201 PDF Datasheet



Module 5202
RS-232 Communication Controller
Features:

  • Simple configuration - no programming required
  • Powerful industry-standard protocol
  • Supports 64 AI, 64 DI, 64 DO, 32 AO
  • Watchdog timer
  • Power saving LED control
  • cCSAus and cULus Class I, Division 2 Hazardous Area Rating
  • UL508 listed
  • 3 year warranty on parts and labor