FlowStation station name. The station name may contain a maximum of 20 characters.
FlowStation station identifier string (e.g. station number, asset identification, etc). The station name may contain a maximum of 20 characters.
The FlowStation Ethernet LAN IP Address in the format: Byte1.Byte2.Byte3.Byte4. The default value is 172.16.100.1. A value of 0.0.0.0 disables the interface.
The time since the last reset of the FlowStation (intentional or otherwise). In the beta version this time is based of an internal status that will wrap around after approximately 49 days.
The IP address assigned to the GPRS modem. Depending on the company providing the wireless account, this address may or may not be accessible from the public internet.
The GPRS modem's status with respect to the network.
0: not registered and not searching
1: registered, home network
2: not registered but searching
3: registration denied
4: unknown
5: registered, roaming.
The current signal strength of the GPRS modem.
0: weakest signal
31: strongest signal
99: unknown or not detectable.
at least 9 is desired for reliable communications